Sl.no.
|
Model Name
|
Specification
|
Applications
|
|
1
|
TY-BNC
|
1.Nominal voltage Un:5V
|
TY-BNC is coaxial signal surge arrester for coaxial computer system like: 100-Base-2, video and camera systems, CCTV, etc. It is used to protect the indirect lightning influence or other instantaneous voltage surge.
|
|
2.Nominal discharge current(8/20μs) line-line In: 5KA
|
|
3.Nominal discharge current(8/20μs) line-PG In :10KA
|
|
4.Voltage protection level line-line Up≤25V
|
|
5.Voltage protection level line-PG Up≤600V
|
|
6.Bandwidth≥20MHz
|
|
7.Max.transfer speed:16M bit/s
|
|
8.Connection input/output: BNC/BNC
|
|
9.Insertion loss:<0.3db
|
|
10.Color:bule,black
|
|
2
|
TY-RJ11
|
1.Nominal voltage Un≤170V
|
TY-RJ signal surge arrester for public telephone system network system like telephone, computer system, etc. It is used to protect the indirect lightning influence or other instantaneous voltage surge.
|
|
2.Nominal current IL:100mA
|
|
3.Nominal discharge current(8/20μs) In: 5KA
|
|
4.Voltage protection level line-line Up≤250V
|
|
5.Voltage protection level line-PG Up≤250V
|
|
6.Max.transfer speed:2M bit/s
|
|
7.Response time<1ns
|
|
8.Connection input/output: RJ11/RJ11
|
|
9.Pinning:3/4
|
|
3
|
TY-RS485
|
1.Nominal voltage Un≤24V
|
TY-RS 485 signal surge arrester is used for supervisory control system, communication system, PLC, MCR, etc. It possess low limiting voltage with high discharge capacity.
|
|
2.Nominal current IL:100mA
|
|
3.Nominal discharge current(8/20μs) In: 5KA
|
|
4.Voltage protection level line-line Up≤65V
|
|
5.Voltage protection level line-PG Up≤65V
|
|
6.Max.transfer speed:2M bit/s
|
|
7.Response time<1ns
|
|
8.Connection input/output: CH3.96 terminal
|
|
4
|
TY-RS485-4
|
1.Nominal voltage Un≤24V
|
TY-RS 485-4 signal surge arrester is used for supervisory control system, communication system, PLC, MCR, etc. It possesses low limiting voltage with high discharge capacity.
|
|
2.Nominal current IL:100mA
|
|
3.Nominal discharge current(8/20μs) In: 5KA
|
|
4.Voltage protection level line-line Up≤65V
|
|
5.Voltage protection level line-PG Up≤65V
|
|
6.Max.transfer speed:2M bit/s
|
|
7.Response time<1ns
|
|
8.Connection input/output: two CH3.96 terminals
|
|
5
|
TY-3 IN 1
|
a. Ac power source:
|
It is used for supervisory control system, etc. where we need protection from lighting and surge for single phase 220V, 24V/36V/48V AC/DC protection and also protection from video, camera or CCTV.
|
|
1.Protection class: Ⅲ/C
|
|
2.Mode of connection: tandem
|
|
3.Nominal voltage Un:220Vac
|
|
4.Voltage protection level Up≤1800V
|
|
5.Max.discharge current (8/20μs)Isn:10KA
|
|
b. 485 control signal
|
|
1.Nominal voltage Un:24Vdc
|
|
2.Voltage protection level Up≤60V
|
|
3.Max.discharge current (8/20μs)Isn:5KA
|
|
c. Video signal
|
|
1.Connection input/output: BNC/BNC
|
|
2.Nominal voltage Un≤24Vdc
|
|
3.Voltage protection level Up:65V/300V
|
|
4.Max.discharge current (8/20μs)Isn:5KA
|
|
5.Max.transfer speed:20M bit/s
|
|
6.Insertion loss:<0.2db
|
|
6
|
TY-RJ45
|
1.Nominal voltage Un:8V
|
TY-RJ 45 is used for protecting Ethernet 100-Base T/Tx, LAN and 100 Base-T (IEEE802.5) from induced lightning and surge currents and static interference.
|
|
2.Nominal current IL:100mA
|
|
3.Nominal discharge current(8/20μs) line-line In:1. 5KA
|
|
4.Nominal discharge current(8/20μs) line-PG In:5KA
|
|
5.Voltage protection level line-line Up≤65V
|
|
6.Voltage protection level line-PG Up≤300V
|
|
7.Max.transfer speed:100M bit/s
|
|
8.Response time<1ns
|
|
9.Connection input/output:
RJ45/RJ45
|
|
10.Pinning:1/2,3/6
|
|
TY-RJ45-M
|
11.Pinning:1-8
|
TY-RJ 45-4E multi connection net signal surge arrester is used for Ethernet 10/100 Base like switch, hub, router, from induced lightning and surge currents and static interference.
It is used to protect Ethernet 100 Base T/Tx, 100Vg-Any-LAN, CDDI, 0-Base-TIEEE802.3, EURO-ISDN, etc. like Hub from damages due to inductive lightning and surge currents and static interference.
|
|
7
|
TY-RJ45-4
|
4 RJ45/RJ45
|
|
TY-RJ45-8
|
8 RJ45/RJ45
|
|
TY-RJ45-12
|
12 RJ45/RJ45
|
|
TY-RJ45-16
|
16 RJ45/RJ45
|
|
8
|
TY-RJ45/24
|
1.Nominal voltage Un:8V
|
|
2.Nominal current IL:100mA
|
|
3.Nominal discharge current(8/20μs) In:5KA
|
|
4.Voltage protection level line-line Up≤35V
|
|
5.Voltage protection level line-PG Up≤300V
|
|
6.Max.transfer speed:100M bit/s
|
|
8.Response time<1ns
|
|
9.Connection input/output: RJ45/RJ45
|
|
10.Pinning:1/2,3/6,4/5,7/8
|
|
9
|
TY-BNC-4
|
1.Max. discharge current (8/20μs) In: 10KA
|
TY-BNC-4E is video signal surge arrester in F, N and BNC connection. Used for TV system, supervisory control system for protecting damages due to inductive lightning and surge currents and static interference.
|
|
2.Insertion loss:<0.2db
|
|
3.Response time:10-12ns
|
|
4.Impedance:75Ω
|
|
5.Connection :F,N,BNC etc
|
|
4 BNC /BNC
|
|
TY-BNC-8
|
8 BNC/BNC
|
|
TY-BNC-12
|
12 BNC/BNC
|
|
TY-BNC-16
|
16 BNC/BNC
|
|
TY-BNC-24
|
24 BNC/BNC
|
|
10
|
TY-DB2504-D
|
1.Pinning : L:2/3 SG7 Pg1
|
|
TY-DB2509-D
|
2.Pinning : L:2/3 3/4/5/6/8/20SG7 Pg1
|
|
|
3.Un=12V,Uc=18V,Isn=5KA,
Max. transfer speed: 1M
|
|
|
|
11
|
TY-DB1509-D
|
1.Pinning:L:2/3 SG5 Pg1
|
|
2.Un=12V,Uc=18V,Isn=5KA,
Max transfer speed:1M
|
|
12
|
TY-DB904-D
|
1.Pinning:L:2/3 SG5 Pg1
|
|
|
2.Un=12V,Uc=18V,Isn=5KA,
Max transfer speed:1M
|
|
TY-DB904-DH
|
1.Pinning:L:2/9/4/1 SG8 Pg1
|
|
2.Un=8V,Uc=15V,Isn=5KA,
Max transfer speed:1M
|
|
TY-DB909-L
|
1.Pinning:L:1/2/3/4/6/7/8/9 SG5 Pg
|
|
2.Un=12V,Uc=18V,Isn=5KA,
Max transfer speed:1M
|
|
13
|
TY6-230
|
1.Nominal voltage Un:12V,24V,36V,48V,110V
|
Is used for protecting equipments operating on 1V to 230V AC/DC from lightning and surge currents.
|